| |
|
|
| Title |
Author |
PDF |
| |
|
|
| Infrared
Thermography for Expert Witness and Legal Documentation |
R.
James Seffrin and Christopher J. Seffrin. |
|
| Defining
the Elements for Successful Infrared Thermography |
R.
James Seffrin. |
|
| Infrared
Thermography Advances Aid Proactive Maintenance |
R.
James Seffrin. |
|
| Infrared
Thermography as a Proactive Tool for Roof Maintenance |
Christopher
J. Seffrin. |
|
NFPA
70E and Infrared Inspections of Electrical Distribution
Systems |
R.
James Seffrin. |
|
| Non-Destructive
Inspection of Steam Traps |
R. James Seffrin. |
|
| OSHA
and Infrared Inspections of Electrical Distribution Systems |
R. James Seffrin. |
|
| Applying
FEA to Perform Heat Transfer Calculations to Increase
the Utility of IR Thermography |
Jack M. Kleinfeld, P.E. |
|
| September
11, 2001: A Thermographer's Experience at Ground Zero |
Carol Ciemiengo |
 |
| Applying
Distance to Spot Ratio Values to Infrared Imagers for
Accurate Temperature Measurement |
Warren
C. Garber & R. James Seffrin |
|
| The
Fine Print: Contract Terms to Watch For and Avoid |
Robert
J. Incollingo, Esq. |
 |
| Confidence
Limits in Temperature Measurements |
G. Raymond Peacock, Temperatures.com,
Inc. |
 |
| Thermal
Imaging for Detetcing Potential SARS Infection |
R. James Seffrin. |
 |
| Infrared
Thermographyt to Detect Refractory Damage in a Fluid
Catalytic Cracking Unit |
Robert K. Weigle |
 |
| The
Use of Infrared Thermography for Steel Process Development&
Monitoring |
Kenneth J. Roush |
 |
| Selecting,
Specifying,and Purchasing Infrared Imagers |
R. James Seffrin |
 |
| "What
Else Can I Inspect" |
John
F. Keane and Robert P. Madding,
FLIR Systems, Inc. |
 |
| Ultrasonic
Tips On Monitoring Bearings For Proper Lubrication and
Wear |
Mark A. Goodman, UE Systems, Inc. |
 |
| Are
you IR Challenged? |
Gregory R. Stockton,
Stockton Infrared Thermographic Services, Inc. |
 |
| Infrared
Inspection Data: What’s Hot and What's Not?
|
Scott Cawlfield, Logos Computer Solutions,
Inc. |
 |
| Liability:Where
Does It Come From And Where Does It End? |
Robert
J. Incollingo, Esq. |
 |
| Applications
of Infrared Thermography for Petrochemical Process Heaters |
Robert K. Weigle |
 |
| Advances
in Applications and Methodologyfor Aerial Infrared Thermography
|
Gregory R. Stockton,
AITscan (Aerial Infrared Thermographers)
A division of
Stockton Infrared Thermographic Services, Inc. |
 |
| Electricity
Conservation Technology–A Revolutionary Way to SaveE
lectricity, Money and Reduce Pollution |
Paul Grover, Kilawatt™ Partners |
 |
| Infrared
Thermography In The Marine Industry |
Skip Handlin, Vice President
Handlin Preventive Maintenance Services, Inc. |
 |
|
Fred
Colbert, President
Colbert Infrared Services, Inc. |
 |
| IR
Thermography as a Tool for the Pest Management Professional
|
Jon L. Grossman, Hi-Tech Inspection
Services, Inc. |
 |
| The
8 Discipline Approach to Problem Solving |
Bill Arnott, Owner,Apex
Infrared |
 |
| Automation
Tips and Techniquesf or GrowingYour Infrared Program |
Scott Cawlfield, Logos Computer Solutions,
Inc. |
 |
| Simplified
Calibration of Radiometric Equipment |
Michael R. Sharlon, President
ACS Calibrations |
 |
| Temperature
Measurement of Plastic Injection Molding Dies
|
James
M. Lies,
President
Infrared Predictive Maintenance |
 |
| Using
Sound Imaging to Enhance Your Diagnosis |
Mark
A. Goodman, VP Engineering, UE Systems, Inc. |
 |
| Images
and Reports: Your Work Product and the Law |
Robert
J. Incollingo, Esq. |
 |
| Infrared
Inspection of Underground Fluid Lines |
Robert K. Weigle, Thermographer, Jersey
Infrared Consultants |
 |
Playing
Hide and Seek with Mold
How an Infrared Thermographer and a Mold Inspector
Can Partner in Their Search for Mold |
Gregory
R. Stockton, Stockton Infrared Thermographic Services,
Inc.
Rachelle Dobbs,Dobbs Enterprises,
Inc. |
 |
| Advanced
Techniques in IR Thermography as a Tool for the Pest Management
Professional |
Jon L. Grossman, Hi-Tech Inspection
Services, Inc. |
 |
| Infrared
Thermography for Stationary Marine Applications |
Skip Handlin, Vice President
Handlin Preventive Maintenance Services, Inc. |
 |
| Common
Misconceptions Relating to Infrared Inspection Ports |
Martin Robinson, Managing Director
Global Maintenance Technologies |
 |
| Thermographic
Documentation of Roof and Building Damage Incurred During
the 2004 Florida Hurricane Season |
James Brady,
President, Level-III Certified Thermographer &
Warren C. Garber,
Level-III Certified Thermographer |
 |
| Implementation
of IR Services in Developing a Sustainable Roof System
Program |
David Seymore, President
David Seymore Contractor Inc. |
 |
| Buried
in Paperwork? Time, Tools, and Trends in the Infrared
Industry |
Scott Cawlfield, Logos Computer Solutions,
Inc. |
 |
| Calibration
and R&R Practices for Reliable Temperature Measurements |
G. Raymond Peacock, Temperatures.com,
Inc. |
 |
| Successful
Use of IR in Pest Management |
Bart Bruni,
Certified Pest Operator
Bestec Exterminators |
 |
| Semi
Conductor Thermography |
Bruce Williams, Intel
Corporation |
 |
| The
Fundamentals of Refractory Inspection with Infrared Thermography |
Sonny James,
Managing Director Thermal Diagnostics Ltd |
 |
| Applying
Infrared Imaging Techniques to Marine Surveying |
John (Jack) N. Allinson, II BS,
J.N. Allinson Associates, Inc. |
 |
| Understanding
Proprietary Infrared Image Files |
Fred Colbert, President
Colbert Infrared Services, Inc. |
 |
| Where
Has All the “Tribal Knowledge” Gone? |
Mark
A. Goodman, VP Engineering, UE Systems, Inc. |
 |
| Trestles
Anyone? A Thermographic Nightmare |
Jon L. Grossman, Hi-Tech Inspection
Services, Inc. |
 |
| A
Thermographer’s Guide to Infrared Windows |
Martin Robinson, Managing Director
Global Maintenance Technologies |
 |
| Corona
and Tracking Conditions in Metal-clad Switchgear Case
Studies |
James Brady,
President, Level-III Certified Thermographer,
Brady Infrared Inspections, Inc. |
 |
| Infrared
Applications in Building Diagnostics |
Ron Lucier,
ITC Training Center
FLIR Systems, Inc. |
 |
| Infrared
“Knowledge Management” |
Scott Cawlfield, Logos Computer Solutions,
Inc. |
 |
| Web
Marketing for Small Business |
G. Raymond Peacock, Temperatures.com,
Inc. |
 |
| The
Business of Infrared Home Inspections |
Bart Bruni,
Certified Pest Operator
Bestec Exterminators |
 |
| An
Infrared View of Inductive Heating |
Michael R. Sharlon, President
Thermasearch, Inc. |
 |
| Destructive
Harmonics in the Infrared World |
Skip Hadlin,
S. Handlin Predictive Maintenance, LLC |
 |
Thermal
Infrared vs. Active Infrared:
A New Technology Begins to be Commercialized
|
Jon L. Grossman, Hi-Tech Inspection
Services, Inc. |
 |
| Infrared
Inspection Windows: Where Do I Start? |
Martin Robinson, Managing Director
Global Maintenance Technologies |
 |
| Methods
of Inspection to Determine the Presence of Potential Arc
Flash Incidents |
Mark A. Goodman, VP Engineering, UE
Systems, Inc. |
 |
| Interpreting
the Images: Data Errors in Thermography – Electrical
& Roofs |
Harley
Denio, President
Oregon Infrared |
 |
| The
Role of Infrared Testing at Data Centers |
Eric Stockton, Director
CompuScanIR™ Division,
Stockton Infrared Thermographic Services, Inc. |
 |
Using
Infrared Thermography to Aid
in Indoor Air Quality Inspection & Mold Remediation |
Lance Eisen,
Chief of Operations & Douglas Hoffman,
Executive Director, NORMI, Inc. |
 |
| Fault
Zone Analysis: Six Part Series on Identifying Motor Defects |
Noah P. Bethel
PdMA Corporation |
 |
The
Importance of Spatial Resolution in Infrared Thermography
Temperature Measurement –
Three Brief Case Studies |
Authors:
Robert P. Madding,Gary L. Orlove, Bernard R. Lyon
Presenter: Ed Kochanek
Infrared Training Center,
FLIR Systems, Inc. |
 |
| Verifying
an Infrared Imager's Calibration |
G. Raymond Peacock, Temperatures.com,
Inc. |
 |
| Using
Infrared Sightglasses to Protect Against Arc-Flash Exposure |
Antony
J. Holliday,
Hawk IR International, Ltd. |
 |
| Active
Thermography: An Overview of Methods and Their Applications
in Use Today |
Michael R. Sharlon, President
Thermasearch, Inc. |
 |
| Inspection
of Steam Reformers and Catalyst Tubes with Infrared Thermography |
Sonny James,
Managing Director Thermal Diagnostics Ltd |
 |
| Thermographic
Inspection of Building and Roof Water Intrusion in the
State of Florida |
James Brady,
President, Level-III Certified Thermographer,
Brady Infrared Inspections, Inc. |
 |
What
to Look for First, When Performing
Infrared Building Surveys |
Gregory
R. Stockton,
Stockton Infrared Thermographic Services, Inc. |
 |
Diagnosis
and Repair of Failing In-floor
Electric Radiant Heating Lines |
Lee Durston,
Forensic Building Scientist,
BCRA |
 |
| Case
Study of a Hotel Missing Insulation |
Tom Mayfield, CIRT,
CIAQT,
Mayfield Thermography Consulting Services, Inc. |
 |
| Infrared
and the Information Age |
Scott Cawlfield, Logos Computer Solutions,
Inc. |
 |
See
What You’ve Been Missing:
How IR Windows Can Help Prevent Arc Flash and Assist with
NFPA 70E Compliance |
Martin Robinson, President and
Tim Rohrer, Director of Sales
IRISS, Inc. |
 |
| Bridging
the Gap: Communicating Motor Reliability to Management
|
Noah P. Bethel
PdMA Corporation |
 |
| How
a Fenestration Professional in New England
Benefits from Use of Infrared Thermal Imaging of Doors
& Windows |
Jay Ray,
founding member of IFSPA; and, R. Olsen |
 |