Using an Isotherm to Detect Potential Condensation Sites

September 10, 2018

Sponsored by:

II_logo
Using an Isotherm to Detect Potential Condensation Sites
Tip written by: Infraspection Institute

Condensation on interior building surfaces can lead to a variety of problems including conditions conducive to mold growth. Used properly, the isotherm feature found on many infrared imagers can be utilized to spot potential condensation sites.

Simply put, dew point is the temperature at which water vapor in the air will cause condensation to form on a surface. When interior building components are cooled to dew point temperature or lower, water vapor will precipitate out of the air causing water to form on the subject component.

For building envelopes, chronic condensation on interior drywall surfaces can cause unsightly staining by trapping dust or smoke particulates in these areas. Chronic condensation on organic building components is also conducive to mold growth. Condensation often goes unnoticed until building occupants notice stains associated with the aforementioned conditions. Fortunately, a thermal imager can be used to detect condensation problems before they become serious.

To utilize a thermal imager to detect potential condensation sites, identify the dew point temperature for the room or areas that you are inspecting. Set your imager’s isotherm function to appear at, and for several degrees below, the dew point temperature. As you inspect high emittance building surfaces from the interior of the building, note any components that cause the isotherm to appear. These areas should then be further investigated for cause and appropriate action taken.

When using an isotherm, be sure to practice proper measurement techniques giving particular consideration to viewing angle, spot measurement size and emissivity settings.

Infrared inspections of building envelopes is one of the many topics covered in the Infraspection Institute Level I Certified Infrared Thermographer® training course. For more information including course locations and dates, visit Infraspection Institute online or call us at 609-239-4788.

Visit Infraspection Institute Web Site

Advertisement

Latest Tips

Ladder Safety - Part 1

November 09, 2026

Autumn IR Inspections to Assess Roof Condition

November 02, 2026

Using an IR Imager to Monitor Drywall Installation

October 26, 2026

Applying Thermography

October 19, 2026

How to Calculate Emittance

October 12, 2026